ADDITIONAL ALTERNATE DEVICES
The following are compatable with 5820XL, 5808, and 5700
SD500-AIM Addressable Input Module
SD500-ANM Addressable Notification Module
SD500-ARM Addressable Relay Module
SD500-LED SLC Annunciator Driver Module
SD500-LIM Loop Isolation Module
SD500-MIM Mini-Input Module
SD500-PS/PSDA Single or Dual Action
Addressable Pull Station
SD500-SDM Smoke Detector Module
SD505-4AB/SD505-6AB Four/Six-Inch Detector Base
SD505-DUCT Addressable Duct Housing
SD505-ADHR Addressable Duct Detector with Built-In Relay
SD505-DTS Addressable Duct Detector Test Switch
Power Supplies, Detectors, Modules, Annunciators, Bases and More
Our IntelliKnight Series boasts a complete line of accessories that lets you bring unparalleled functionality and control to any job. IntelliKnight’s addressable
power supplies, bases, detectors, modules and pull stations are all specifically engineered to ensure your installs and maintenance remain simple and eco-
nomical. Combine these accessories with the IntelliKnight’s built-in digital communicator for the most powerful and easy-to-use addressable solution in the
industry. All of our accessories are compatible with all three of our addressable fire alarm control panels.
ADDRESSABLE FIRE ALARM ACCESSORIES
5895XL Intelligent Power Module
• Six amps of output power
• Six programmable Flexput
TM
I/O circuits
• Two Form C relay circuits
• Built-in synchronization for System Sensor
®
,
Wheelock, Gentex
®
, Faraday and AMSECO
5496 Addressable Power Supply
• Six amps of output power
• Four programmable output circuits
• Built-in synchronization for System Sensor
®
,
Wheelock, Gentex
®
, Faraday and AMSECO
5883 Relay Interface Board
• 10 programmable Form C relays
5865-3/5865-4 Remote LED Annunciator
• 30 programmable LEDs
• Fits standard 3- or 4-gang electrical box
• Up to eight annunciators per panel
5860/5860R Remote LCD Annunciator
• 80-character backlit annunciator
• Available in gray or red
• Surface or flush-mount
5824 Serial/Parallel Module
5880 LED Input/Output Module
SILENT KNIGHT PROTOCOL DEVICES
SK-PHOTO - Photoelectric Detector
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-PHOTO-T - Photoelectric Thermal Detector
• 135°F fixed temperature thermal sensing
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-ION - Ionization Smoke Detector
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-HEAT - 135°F Fixed Temperature Detector
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-HEAT-HT - 190°F Fixed Temperature Detector
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-HEAT-ROR - 135°F Fixed Temperature
Rate of Rise Detector
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-MONITOR - Monitor Module
• Rotary address switch
• LED indicator and wall plate included
SK-MON-10 Ten Input Monitor Module
• Rotary address switch
• Unused addresses may be disabled
SK-MINIMON Monitor Module
• Rotary address switch
• Compact footprint allows it to fit inside
devices or in junction boxes behind devices
SK-ISO Fault Isolator Module
• LED indicator and wall plate included
• Mounts in standard 4“ junction box’
ALTERNATE PROTOCOL DEVICES
SD505-AHS Addressable Heat Detector
• Programmable temperature range
• Low-profile
SD505-AIS Addressable Ionization Type
Smoke Detector
• Low-profile
• Supervised
• Provides drift compensation and detector
sensitivity test
SD505-APS Addressable Photoelectric Type
Smoke Detector
• Low-profile
• Supervised
• Provides drift compensation and detector
sensitivity test
SD505-6SB 6" Addressable Sounder Base
• Adds audible output function
• Single station or multi-station applications
SD505-6RB 6" Addressable Relay Base
• Provides relay output function
• Normally open or closed relay
• Compatible with our photoelectric,
ionization and heat detectors
SD505-6IB 6" Isolator Base
• Isolates short circuited wiring on an SLC
loop without shutting down the entire loop
B200SR - Sounder Base
• Adds audible output function
• Compatible with existing B501BH series
• Built-in synchronization
SK-ACCLIMATE Multi-Criteria Photoelectric Detector
with Thermal Sensing
• 135°F fixed temperature
• Rotary address switch
• Dual LEDs for 360° visibility
• B210LP 6” intelligent base
and trim ring included
SK-DUCT -Photoelectric Duct Detector
• Head included
• Flexible housing footprint
– square or rectangular
• Broad operating temperature range
-4°F to 158°F and broad humidity range
(0% to 95% non-condensing)
SK-BEAM - Single-Ended Reflected Beam
Smoke Detector
• Rotary address switch
• Reflector kit included
• Range 16-230 feet; 230-328 feet
with optional long range kit
SK-BEAM-T - Single-Ended Reflected Beam
Smoke Detector
• Built in test feature
• Rotary address switch
• Reflector kit included
• Range 16-230 feet; 230-328 feet
with optional long range kit
SK-MONITOR-2 - Dual Monitor Module
• Rotary address switch
• LED indicator and wall plate included
• Mounts in standard 4“ junction box
SK-CONTROL - Supervised Control Module
• Rotary address switch
• LED indicator and wall plate included
• Mounts in standard 4“ junction box
SK-CONTROL-6 - Six Circuit Supervised Control Module
• Rotary address switch
• Unused addresses may be disabled
SK-RELAY - Relay Control Module
• (2) 3 Amp Form C relay outputs
• Rotary address switch
• LED indicator and wall plate included
• Mounts in standard 4“ junction box
SK-RELAY-6 - Six Relay Control Module
• (6) 3 Amp Form C relay outputs
• Rotary address switch
• Unused addresses may be disabled
SK-ZONE - Zone Interface Module
• Rotary address switch
• LED indicator and wall plate included
• Mounts in standard 4“ junction box
SK-ZONE-6 - Six Zone Interface Module
• Rotary address switch
• Unused addresses may be disabled