Installation Instructions
151174 3-9
3.5.5 Battery Connections
The transformer provides power for the 5083 and 5084 main units and charging current for the
12 VDC backup battery. In the event of a power outage, the 12 VDC, 1.2 AH battery (shipped
with the unit) will provide enough current to run the system for a minimum of 2 hours. The
actual time will depend on how much the system is used. All programmed data will be stored
in Flash memory if AC power is lost and the backup battery becomes depleted.
To connect the backup battery (Model 6912).
1. Connect the black battery cable to the minus (-) terminal of the battery. (See Figure 3-7 for
battery cable location.)
2. Connect the red battery cable to the positive (+) terminal of the battery.
Figure 3-7 Backup Battery Connection
Battery Wiring
Harness Provided