Series 5000 Entry System Installation/Operation Manual
6-2 151174
6.3 Auxiliary Door Access Operation
The auxiliary door may be programmed to be active during certain hours of the day. It may
only be activated during the time that the Aux Time Window. When a visitor calls a tenant, the
user can press a 9 to activate the Auxiliary relay. The auxiliary relay may also be activated by
entering operation mode 4 (see Section 4.2.5). If the Auxiliary Relay is programmed for
“Continuous” then the auxiliary relay will remain active for the entire duration of the Aux
Time Window (see Section 4.2.3 step 7 through step 10 to set Aux time window parameters).
6.4 Postal Access Operation
Turning the postal key in the lock will automatically open the door. The mail carrier then has
access to the mail boxes inside the building.
6.5 Door Attendant Notification Operation
In installations where a door attendant is stationed at the control panel, a tenant can call the
attendant to inform him that they will have a guest arriving and provide the attendant with the
visitors name, and the approximate time of arrival. When the tenant wishes to contact the door
attendant they dial the phone number to the control panel. When the control panel detects ring
voltage the auxiliary relay activates a sounding device (see Section 3.5.13 for installation
example of sounding device) to notify the attendant of an incoming phone call. When the
sounding device activates the attendant presses the 5 button to answer. The attendant can hang
up the phone by pressing the * button.