Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
8
When a touchpad is in use and access is attempted at another location, the second location will
receive a SYSTEM BUSY message. However, the system will respond to a panic key activa-
tion or exit request at the second location. Touchpads are assigned to a group of areas for area
control (see Section 8.5 of this manual).
4.2 Touchpad Functions
The Model 4724 Control Expander provides the following additional touchpad functions:
4.2.1 Display Alarms
Press the MEM key to display alarms.
4.2.2 Display Troubles and Supervisories
Press the STAT key to display troubles or supervisories.
4.2.3 Toggle X-10s
To toggle X-10 Modules on and off, press a number from 11-42, then * or CODE 2, followed
by either “1” for on or “0” for off.
■ Numbers 11-26 activate modules 1-16 from House Code 1.
■ Numbers from 27-42 activate modules 1-16 from House Code 2.
The house codes for each section are programmed into the EEPROM (electrically erasable pro-
grammable read-only memory). The display shows the actual house code and module address
activated.
Table 1: Panic Key Zones
Zone Generated by Key
Station 0 1 2 3 4 5 6 7
Duress Code 145 149 153 157 161 165 169 173
Keys
Police 146 150 154 158 162 166 170 174
Aux 147 151 155 159 163 167 171 175
Fire 148 152 156 160 164 168 172 176
Station 8 9 10 11 12 13 14 15
Duress Code 177 181 185 189 193 197 201 205
Keys
Police 178 182 186 190 194 198 202 206
Aux 179 183 187 191 195 199 203 207
Fire 180 184 188 192 196 200 204 208